Check Whether You Need to Measure
OSHA's rule of thumb: the work area is too noisy if a worker cannot be understood without raising their voice while talking to a co-worker 3 feet away. NIOSH puts it in decibels: sounds around 85 dBA often mean raising your voice to be heard at 3 feet, and at 95 dBA or more you likely have to shout.
A phone gives a useful first reading. Our workplace noise meter shows the level and the safe exposure time against the 85 dBA limit. It is a screening check, not a compliance measurement.
Step 1: Walk the Site With a Sound Level Meter
OSHA uses a sound level meter for screening. During the first walkaround, it finds the areas with raised noise levels, where full-shift dosimetry should be done. It is also used to spot-check dosimeters and to work out a dose when no dosimeter is available.
- Use a Type 2 or Type 1 meter. OSHA counts a Type 2 reading as accurate to ±2 dBA, the minimum precision it requires. The types of sound level meters explains the classes.
- Set A-weighting and slow response. Slow response has a 1-second time constant; fast has 125 milliseconds. See what dBA means for why A-weighting is used.
- Hold the microphone in the worker's hearing zone, which OSHA defines as a 2-foot-wide sphere around the head.
- Use a wind screen. It cuts the effect of air movement and contact, and protects the microphone from dust and moisture.
Note the level at each workstation and task. Our sound level meters guide covers handheld Class 2 meters, and the sound level meter comparison lists more models side by side.
Step 2: Measure Each Worker With a Dosimeter
A dosimeter is worn by the worker and adds up their exposure over the shift. OSHA's standard requires personal sampling where workers move between areas, the level varies widely, or impulse noise is a large part of it, unless area sampling can be shown to give the same results.
OSHA sets up dosimeters with these settings:
- Exchange rate: 5 dB.
- Frequency weighting: A. Response: slow.
- Criterion level: 90 dBA.
- Threshold: 80 dBA for the action level, 90 dBA for the permissible exposure limit. Many dosimeters record both at once.
Clip the dosimeter to the belt or shoulder, with the microphone on the shoulder pointing straight up. OSHA's standard counts every continuous, intermittent, and impulsive sound from 80 to 130 dB in the measurement.
Step 3: Calibrate Before and After
Calibrate the meter and the dosimeters before the measurement and again after it, and record both checks. OSHA's own inspectors can only cite with equipment that has a periodic calibration certificate from the past 12 months, plus those documented checks before and after.
Step 4: Compare the Results With the Limits
OSHA's action level is an 85 dBA TWA, a 50% dose. At or above it, the employer needs a hearing conservation program and must tell each worker their results. The permissible exposure limit is a 90 dBA TWA, a 100% dose. For each 5 dB more, the allowed time halves:
- 90 dBA: 8 hours.
- 95 dBA: 4 hours.
- 100 dBA: 2 hours.
- 105 dBA: 1 hour.
- 110 dBA: 30 minutes.
- 115 dBA: 15 minutes or less.
Impulse or impact noise should not exceed a 140 dB peak. NIOSH recommends a stricter limit: 85 dBA over 8 hours, with the time halved for every 3 dB more. How loud is too loud sets these out side by side.
Measure again whenever a change in production, process, equipment, or controls raises the noise enough to put more workers at or above the action level, or to make the hearing protection in use too weak. Workers or their representatives must be given the chance to observe the monitoring.
Using a Phone App